Skip to main navigation Skip to search Skip to main content

Development and evaluation of methodologies for whole mitochondrial DNA sequencing using Oxford Nanopore Technologies MinION Flongle Flow Cells within a forensic human identification context

  • Jie Tang

Student thesis: Master's Thesis

Abstract

Mass fatality incidents (MFIs) often involve a large number of victims and harsh environmental conditions, making conventional forensic identification extremely challenging. In many of these cases, DNA testing becomes the only reliable method of establishing identity. Traditional PCR-based short tandem repeat (STR) profiling remains the gold standard for forensic identification due to its high accuracy, however, its effectiveness is reduced when nuclear DNA is fragmented, degraded, or present in low quantities. These constraints, together with high costs, limited multiplexing capacity, and the reliance on specialised laboratory environments, restrict STR profiling in disaster settings. In contrast, mitochondrial DNA (mtDNA) offers distinct advantages because of its high copy number, maternal inheritance, and increased resilience in compromised samples, making it especially valuable when STRs fail. The Oxford Nanopore Technologies (ONT) MinION device provides benefits through its portability, rapid real-time sequencing, long-read capability, and ability to detect diverse genetic markers simultaneously. With recent chemistry updates achieving accuracies approaching Q20 (reflecting 99% base-calling accuracy), the ONT MinION presents a promising and accessible tool for mtDNA analysis in challenging forensic environments such as MFIs. This thesis investigated the potential of whole mtDNA sequencing using the ONT MinION device with a Flongle flow cell (a low-cost, portable sequencing option) through two complementary aims.

Aim 1 conducted a scoping review following a PICOS (Population, Intervention, Comparison, Outcomes, Study design) framework to systematically evaluate 22 studies examining mtDNA usage in forensic human identification. This work focused on identifying the variation of mtDNA markers used in human identification research, excluding commercial kits and ancient DNA related investigations. The review revealed a clear methodological progression from early Sanger sequencing of the control region to targeted coding-region SNP panels but identified a major gap: only one study sequenced the full mitochondrial genome for human identification purposes. Interestingly, none of the studies identified applied long-read technologies such as Oxford Nanopore Technologies (ONT) or PacBio. Because approximately 75% of informative mtDNA variation lies outside HVI/HVII, current region-limited approaches underutilise the full discriminatory potential of mtDNA. This further sets up the need for whole mitochondrial sequencing as an additional option for human identification.

Aim 2 proposed to address this gap by evaluating the Flongle flow cell as a vehicle for whole mitochondrial sequencing. There were two amplification methods, Long-Range PCR and QIAGEN Repli-G, for whole mtDNA amplification evaluated and compared to the Genome in a Bottle (GIAB) reference datasets. Results found that the Long-Range PCR demonstrating superior accuracy and fewer artefacts, compared to the Repli-G amplification method. However, both methods provided high concordance with the reference dataset, as well as mapping to the maternal lineage comparison which highlighted the potential of the Flongle for full-mtDNA sequencing for kinship assessment. A major limitation of this work was a low sequencing depth due to Flongle’s restricted output and over-multiplexing, highlighted the need for higher-capacity ONT platforms and evaluation using degraded DNA.

Overall, there is some feasibility and forensic value of whole mitochondrial sequencing using a portable ONT platform, however, future work should focus on higher capacity flow cells, such as the MinION flow cell to allow for more comprehensive mtDNA analysis. Future optimisation and validation on degraded samples will also be essential to ensure there is real-world forensic implementation, especially in challenging scenarios such as MFIs where rapid, portable, and informative DNA technologies are most needed.
Date of Award18 Jun 2026
Original languageEnglish
SupervisorPaul Dunn (Supervisor) & Jasmine Connell (Supervisor)

Cite this

'