Ultrasound imaging of the distal radioulnar joint: A new method to assess ulnar radial translation in forearm rotation

C E Oldfield, M R Boland, D Greybe, W Hing

Research output: Contribution to journalArticleResearchpeer-review

4 Citations (Scopus)

Abstract

A cross-sectional reliability study was conducted with 23 normal participants to establish normal values, and the repeatability and validity of distal radioulnar joint translation measurements using ultrasound imaging. Static transverse images of maximal supination, neutral and maximal pronation were examined to assess translation, using a method consistent with the rheumatoid arthritis subluxation ratio. Translation while gripping a 1 kg weight in supinated and pronated positions was then compared with non-gripping translation. There was significantly more ulnar radial translation found with pronation than supination, when compared with neutral. Gripping in pronation did not produce statistically significant changes in translation, whereas the changes produced by gripping in supination were significant. Internal consistency was deemed very high and the rheumatoid arthritis subluxation ratio values measured using ultrasound imaging were consistent with previously documented values measured by computerized tomography. This study demonstrated that translational movement of the distal radioulnar joint can be reliably detected in healthy participants using ultrasound imaging. This may reduce dependency on other imaging modalities to diagnose distal radioulnar joint instability.

LEVEL OF EVIDENCE: 2.

Original languageEnglish
Pages (from-to)389-394
Number of pages6
JournalJournal of Hand Surgery: European Volume
Volume42
Issue number4
DOIs
Publication statusPublished - 1 May 2017
Externally publishedYes

Fingerprint

Pronation
Supination
Forearm
Ultrasonography
Joints
Rheumatoid Arthritis
Joint Instability
Healthy Volunteers
Reference Values
Cross-Sectional Studies
Tomography
Weights and Measures

Cite this

@article{f1ddead41bdd43f89d964a20b0af6659,
title = "Ultrasound imaging of the distal radioulnar joint: A new method to assess ulnar radial translation in forearm rotation",
abstract = "A cross-sectional reliability study was conducted with 23 normal participants to establish normal values, and the repeatability and validity of distal radioulnar joint translation measurements using ultrasound imaging. Static transverse images of maximal supination, neutral and maximal pronation were examined to assess translation, using a method consistent with the rheumatoid arthritis subluxation ratio. Translation while gripping a 1 kg weight in supinated and pronated positions was then compared with non-gripping translation. There was significantly more ulnar radial translation found with pronation than supination, when compared with neutral. Gripping in pronation did not produce statistically significant changes in translation, whereas the changes produced by gripping in supination were significant. Internal consistency was deemed very high and the rheumatoid arthritis subluxation ratio values measured using ultrasound imaging were consistent with previously documented values measured by computerized tomography. This study demonstrated that translational movement of the distal radioulnar joint can be reliably detected in healthy participants using ultrasound imaging. This may reduce dependency on other imaging modalities to diagnose distal radioulnar joint instability.LEVEL OF EVIDENCE: 2.",
author = "Oldfield, {C E} and Boland, {M R} and D Greybe and W Hing",
note = "{\circledC} The Author(s) 2016.",
year = "2017",
month = "5",
day = "1",
doi = "10.1177/1753193416640464",
language = "English",
volume = "42",
pages = "389--394",
journal = "Journal of Hand Surgery: European Volume",
issn = "0266-7681",
publisher = "SAGE Publications Ltd",
number = "4",

}

Ultrasound imaging of the distal radioulnar joint : A new method to assess ulnar radial translation in forearm rotation. / Oldfield, C E; Boland, M R; Greybe, D; Hing, W.

In: Journal of Hand Surgery: European Volume, Vol. 42, No. 4, 01.05.2017, p. 389-394.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Ultrasound imaging of the distal radioulnar joint

T2 - A new method to assess ulnar radial translation in forearm rotation

AU - Oldfield, C E

AU - Boland, M R

AU - Greybe, D

AU - Hing, W

N1 - © The Author(s) 2016.

PY - 2017/5/1

Y1 - 2017/5/1

N2 - A cross-sectional reliability study was conducted with 23 normal participants to establish normal values, and the repeatability and validity of distal radioulnar joint translation measurements using ultrasound imaging. Static transverse images of maximal supination, neutral and maximal pronation were examined to assess translation, using a method consistent with the rheumatoid arthritis subluxation ratio. Translation while gripping a 1 kg weight in supinated and pronated positions was then compared with non-gripping translation. There was significantly more ulnar radial translation found with pronation than supination, when compared with neutral. Gripping in pronation did not produce statistically significant changes in translation, whereas the changes produced by gripping in supination were significant. Internal consistency was deemed very high and the rheumatoid arthritis subluxation ratio values measured using ultrasound imaging were consistent with previously documented values measured by computerized tomography. This study demonstrated that translational movement of the distal radioulnar joint can be reliably detected in healthy participants using ultrasound imaging. This may reduce dependency on other imaging modalities to diagnose distal radioulnar joint instability.LEVEL OF EVIDENCE: 2.

AB - A cross-sectional reliability study was conducted with 23 normal participants to establish normal values, and the repeatability and validity of distal radioulnar joint translation measurements using ultrasound imaging. Static transverse images of maximal supination, neutral and maximal pronation were examined to assess translation, using a method consistent with the rheumatoid arthritis subluxation ratio. Translation while gripping a 1 kg weight in supinated and pronated positions was then compared with non-gripping translation. There was significantly more ulnar radial translation found with pronation than supination, when compared with neutral. Gripping in pronation did not produce statistically significant changes in translation, whereas the changes produced by gripping in supination were significant. Internal consistency was deemed very high and the rheumatoid arthritis subluxation ratio values measured using ultrasound imaging were consistent with previously documented values measured by computerized tomography. This study demonstrated that translational movement of the distal radioulnar joint can be reliably detected in healthy participants using ultrasound imaging. This may reduce dependency on other imaging modalities to diagnose distal radioulnar joint instability.LEVEL OF EVIDENCE: 2.

UR - http://www.scopus.com/inward/record.url?scp=85018347523&partnerID=8YFLogxK

U2 - 10.1177/1753193416640464

DO - 10.1177/1753193416640464

M3 - Article

VL - 42

SP - 389

EP - 394

JO - Journal of Hand Surgery: European Volume

JF - Journal of Hand Surgery: European Volume

SN - 0266-7681

IS - 4

ER -