Measuring line-related bacteraemia in intensive care patients

M. L. McLaws, C. Murphy, P. Taylor, N. Coroneos

Research output: Contribution to journalArticleResearchpeer-review

7 Citations (Scopus)

Abstract

All patients with an intramuscular device in the intensive care units at Prince of Wales and Prince Henry Hospitals between July and September 1995 were followed for the development of line-related bacteraemia per 1000 line days. Cases of sepsis related to an intravascular device were identified using a case definition which incorporated clinical and laboratory parameters. Data were collected prospectively for the dates of insertion and removal of devices for 188 lines inserted in 69 patients. The majority (90%) of lines had both date of insertion and removal documented allowing the calculation of the rate of primary bacteraemia over 832 at-risk line days. Multiple concurrent lines were more common (88.4%) than single lines, with one central and one or two peripheral lines being the most common (42.3%) combination. Five cases of bacteraemia were diagnosed clinically and confirmed microbiologically. The incidence density of primary bacteraemia was 6.0 per 1000 line days (CI(95%) 5.7-6.3).

Original languageEnglish
Pages (from-to)282-286
Number of pages5
JournalAnaesthesia and Intensive Care
Volume26
Issue number3
Publication statusPublished - 1 Jun 1998
Externally publishedYes

Fingerprint

Critical Care
Bacteremia
Device Removal
Equipment and Supplies
Wales
Intensive Care Units
Sepsis
Incidence

Cite this

McLaws, M. L., Murphy, C., Taylor, P., & Coroneos, N. (1998). Measuring line-related bacteraemia in intensive care patients. Anaesthesia and Intensive Care, 26(3), 282-286.
McLaws, M. L. ; Murphy, C. ; Taylor, P. ; Coroneos, N. / Measuring line-related bacteraemia in intensive care patients. In: Anaesthesia and Intensive Care. 1998 ; Vol. 26, No. 3. pp. 282-286.
@article{591d17122fee4310b47ecb17d5aa97dc,
title = "Measuring line-related bacteraemia in intensive care patients",
abstract = "All patients with an intramuscular device in the intensive care units at Prince of Wales and Prince Henry Hospitals between July and September 1995 were followed for the development of line-related bacteraemia per 1000 line days. Cases of sepsis related to an intravascular device were identified using a case definition which incorporated clinical and laboratory parameters. Data were collected prospectively for the dates of insertion and removal of devices for 188 lines inserted in 69 patients. The majority (90{\%}) of lines had both date of insertion and removal documented allowing the calculation of the rate of primary bacteraemia over 832 at-risk line days. Multiple concurrent lines were more common (88.4{\%}) than single lines, with one central and one or two peripheral lines being the most common (42.3{\%}) combination. Five cases of bacteraemia were diagnosed clinically and confirmed microbiologically. The incidence density of primary bacteraemia was 6.0 per 1000 line days (CI(95{\%}) 5.7-6.3).",
author = "McLaws, {M. L.} and C. Murphy and P. Taylor and N. Coroneos",
year = "1998",
month = "6",
day = "1",
language = "English",
volume = "26",
pages = "282--286",
journal = "Anaesthesia and Intensive Care",
issn = "0310-057X",
publisher = "Australian Society of Anaesthetists",
number = "3",

}

McLaws, ML, Murphy, C, Taylor, P & Coroneos, N 1998, 'Measuring line-related bacteraemia in intensive care patients' Anaesthesia and Intensive Care, vol. 26, no. 3, pp. 282-286.

Measuring line-related bacteraemia in intensive care patients. / McLaws, M. L.; Murphy, C.; Taylor, P.; Coroneos, N.

In: Anaesthesia and Intensive Care, Vol. 26, No. 3, 01.06.1998, p. 282-286.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Measuring line-related bacteraemia in intensive care patients

AU - McLaws, M. L.

AU - Murphy, C.

AU - Taylor, P.

AU - Coroneos, N.

PY - 1998/6/1

Y1 - 1998/6/1

N2 - All patients with an intramuscular device in the intensive care units at Prince of Wales and Prince Henry Hospitals between July and September 1995 were followed for the development of line-related bacteraemia per 1000 line days. Cases of sepsis related to an intravascular device were identified using a case definition which incorporated clinical and laboratory parameters. Data were collected prospectively for the dates of insertion and removal of devices for 188 lines inserted in 69 patients. The majority (90%) of lines had both date of insertion and removal documented allowing the calculation of the rate of primary bacteraemia over 832 at-risk line days. Multiple concurrent lines were more common (88.4%) than single lines, with one central and one or two peripheral lines being the most common (42.3%) combination. Five cases of bacteraemia were diagnosed clinically and confirmed microbiologically. The incidence density of primary bacteraemia was 6.0 per 1000 line days (CI(95%) 5.7-6.3).

AB - All patients with an intramuscular device in the intensive care units at Prince of Wales and Prince Henry Hospitals between July and September 1995 were followed for the development of line-related bacteraemia per 1000 line days. Cases of sepsis related to an intravascular device were identified using a case definition which incorporated clinical and laboratory parameters. Data were collected prospectively for the dates of insertion and removal of devices for 188 lines inserted in 69 patients. The majority (90%) of lines had both date of insertion and removal documented allowing the calculation of the rate of primary bacteraemia over 832 at-risk line days. Multiple concurrent lines were more common (88.4%) than single lines, with one central and one or two peripheral lines being the most common (42.3%) combination. Five cases of bacteraemia were diagnosed clinically and confirmed microbiologically. The incidence density of primary bacteraemia was 6.0 per 1000 line days (CI(95%) 5.7-6.3).

UR - http://www.scopus.com/inward/record.url?scp=0031748804&partnerID=8YFLogxK

M3 - Article

VL - 26

SP - 282

EP - 286

JO - Anaesthesia and Intensive Care

JF - Anaesthesia and Intensive Care

SN - 0310-057X

IS - 3

ER -