Is measurement error altered by participation in a physical activity intervention?

Elisabeth Winkler, Lauren Waters, Elizabeth G. Eakin, Brianna Fjeldsoe, Neville Owen*, Marina Reeves

*Corresponding author for this work

Research output: Contribution to journalReview articleResearchpeer-review

Abstract

Purpose
There is no “gold standard” measure for moderate to vigorous physical activity (MVPA); some error is inherent to self-report and device-based measures. Few studies have examined agreement between self-report and device-based measures in the intervention trial context or whether the difference between measures is influenced by intervention participation.

Methods
MVPA was measured at baseline and after 6 months by Active Australia Survey (AAS) and by the GT1M accelerometer (≥1952 counts per minute) in the intervention (n = 135) and usual care control (n = 141) participants of a randomized trial targeting weight loss by MVPA increases and energy intake reductions in adults with type 2 diabetes. Agreement (for each group at each assessment) was examined using the Bland–Altman approach and regression-based modeling. Because the differences between MVPA measures varied with average values ([AAS + GT1M] / 2), they were examined as a percentage of average physical activity. t-tests were used to assess unadjusted group differences and changes over time. ANCOVA models tested intervention effects on measurement error at follow-up, adjusted for baseline.

Results
Agreement worsened, and variability in the difference measures became greater, as the average amount of MVPA increased. Measurement error differed significantly between groups at follow-up (P = 0.010) but not at baseline (P = 0.157) and changed significantly within the intervention group (P = 0.001) but not the control group (P = 0.164). There was a statistically significant effect of the intervention on measurement error (P = 0.026).

Conclusions
Measurement error of self-report relative to the accelerometer appeared to be affected by intervention. Because measurement error cannot be definitively attributed to self-report or accelerometer, it would be prudent to measure both in future studies.
Original languageEnglish
Pages (from-to)1004
Number of pages1011
JournalMedicine and Science in Sports and Exercise
Volume45
Issue number5
DOIs
Publication statusPublished - May 2013
Externally publishedYes

Fingerprint

Dive into the research topics of 'Is measurement error altered by participation in a physical activity intervention?'. Together they form a unique fingerprint.

Cite this