Effects of upper and lower body wearable resistance on spatio-temporal and kinetic parameters during running

Grace A Couture, Kim D Simperingham, John B Cronin, Anna V Lorimer, Andrew E Kilding, Paul Macadam

Research output: Contribution to journalArticleResearchpeer-review

Abstract

Wearable resistance training involves added load attached directly to the body during sporting movements. The effects of load position during running are not yet fully established. Therefore, the purpose of this research was to determine spatio-temporal and kinetic characteristics during submaximal running using upper, lower and whole-body wearable resistance (1-10% body mass (BM)). Twelve trained male runners completed eight 2-min treadmill running bouts at 3.9 m/s with and without wearable resistance. The first and last bouts were unloaded, while the middle 6 were randomised wearable resistance conditions: upper body (UB) 5% BM, lower body (LB) 1%, 3%, 5% BM and whole body (WB) 5%, 10% BM. Wearable resistance of 1-10% BM resulted in a significant increase in heart rate (5.40-8.84%), but minimal impact on spatio-temporal variables. Loads of 5% BM and greater caused changes in vertical stiffness, vertical and horizontal force, and impulse. Functional and effective propulsive force (2.95%, 2.88%) and impulse (3.40%, 3.38%) were significantly (p < 0.05) greater with LB5% than UB5%. Wearable resistance may be used to increase muscular kinetics during running without negatively impacting spatio-temporal variables. The application of these findings will vary depending on athlete goals. Future longitudinal studies are required to validate training contentions.

Original languageEnglish
Pages (from-to)1-19
Number of pages19
JournalSports Biomechanics
DOIs
Publication statusE-pub ahead of print - 16 Oct 2018
Externally publishedYes

Fingerprint

Running
Resistance Training
Athletes
Longitudinal Studies
Heart Rate
Research

Cite this

Couture, G. A., Simperingham, K. D., Cronin, J. B., Lorimer, A. V., Kilding, A. E., & Macadam, P. (2018). Effects of upper and lower body wearable resistance on spatio-temporal and kinetic parameters during running. Sports Biomechanics, 1-19. https://doi.org/10.1080/14763141.2018.1508490
Couture, Grace A ; Simperingham, Kim D ; Cronin, John B ; Lorimer, Anna V ; Kilding, Andrew E ; Macadam, Paul. / Effects of upper and lower body wearable resistance on spatio-temporal and kinetic parameters during running. In: Sports Biomechanics. 2018 ; pp. 1-19.
@article{ba9b1288a9414c69b2bae600b72b6061,
title = "Effects of upper and lower body wearable resistance on spatio-temporal and kinetic parameters during running",
abstract = "Wearable resistance training involves added load attached directly to the body during sporting movements. The effects of load position during running are not yet fully established. Therefore, the purpose of this research was to determine spatio-temporal and kinetic characteristics during submaximal running using upper, lower and whole-body wearable resistance (1-10{\%} body mass (BM)). Twelve trained male runners completed eight 2-min treadmill running bouts at 3.9 m/s with and without wearable resistance. The first and last bouts were unloaded, while the middle 6 were randomised wearable resistance conditions: upper body (UB) 5{\%} BM, lower body (LB) 1{\%}, 3{\%}, 5{\%} BM and whole body (WB) 5{\%}, 10{\%} BM. Wearable resistance of 1-10{\%} BM resulted in a significant increase in heart rate (5.40-8.84{\%}), but minimal impact on spatio-temporal variables. Loads of 5{\%} BM and greater caused changes in vertical stiffness, vertical and horizontal force, and impulse. Functional and effective propulsive force (2.95{\%}, 2.88{\%}) and impulse (3.40{\%}, 3.38{\%}) were significantly (p < 0.05) greater with LB5{\%} than UB5{\%}. Wearable resistance may be used to increase muscular kinetics during running without negatively impacting spatio-temporal variables. The application of these findings will vary depending on athlete goals. Future longitudinal studies are required to validate training contentions.",
author = "Couture, {Grace A} and Simperingham, {Kim D} and Cronin, {John B} and Lorimer, {Anna V} and Kilding, {Andrew E} and Paul Macadam",
year = "2018",
month = "10",
day = "16",
doi = "10.1080/14763141.2018.1508490",
language = "English",
pages = "1--19",
journal = "Sports Biomechanics",
issn = "1476-3141",
publisher = "Routledge",

}

Effects of upper and lower body wearable resistance on spatio-temporal and kinetic parameters during running. / Couture, Grace A; Simperingham, Kim D; Cronin, John B; Lorimer, Anna V; Kilding, Andrew E; Macadam, Paul.

In: Sports Biomechanics, 16.10.2018, p. 1-19.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Effects of upper and lower body wearable resistance on spatio-temporal and kinetic parameters during running

AU - Couture, Grace A

AU - Simperingham, Kim D

AU - Cronin, John B

AU - Lorimer, Anna V

AU - Kilding, Andrew E

AU - Macadam, Paul

PY - 2018/10/16

Y1 - 2018/10/16

N2 - Wearable resistance training involves added load attached directly to the body during sporting movements. The effects of load position during running are not yet fully established. Therefore, the purpose of this research was to determine spatio-temporal and kinetic characteristics during submaximal running using upper, lower and whole-body wearable resistance (1-10% body mass (BM)). Twelve trained male runners completed eight 2-min treadmill running bouts at 3.9 m/s with and without wearable resistance. The first and last bouts were unloaded, while the middle 6 were randomised wearable resistance conditions: upper body (UB) 5% BM, lower body (LB) 1%, 3%, 5% BM and whole body (WB) 5%, 10% BM. Wearable resistance of 1-10% BM resulted in a significant increase in heart rate (5.40-8.84%), but minimal impact on spatio-temporal variables. Loads of 5% BM and greater caused changes in vertical stiffness, vertical and horizontal force, and impulse. Functional and effective propulsive force (2.95%, 2.88%) and impulse (3.40%, 3.38%) were significantly (p < 0.05) greater with LB5% than UB5%. Wearable resistance may be used to increase muscular kinetics during running without negatively impacting spatio-temporal variables. The application of these findings will vary depending on athlete goals. Future longitudinal studies are required to validate training contentions.

AB - Wearable resistance training involves added load attached directly to the body during sporting movements. The effects of load position during running are not yet fully established. Therefore, the purpose of this research was to determine spatio-temporal and kinetic characteristics during submaximal running using upper, lower and whole-body wearable resistance (1-10% body mass (BM)). Twelve trained male runners completed eight 2-min treadmill running bouts at 3.9 m/s with and without wearable resistance. The first and last bouts were unloaded, while the middle 6 were randomised wearable resistance conditions: upper body (UB) 5% BM, lower body (LB) 1%, 3%, 5% BM and whole body (WB) 5%, 10% BM. Wearable resistance of 1-10% BM resulted in a significant increase in heart rate (5.40-8.84%), but minimal impact on spatio-temporal variables. Loads of 5% BM and greater caused changes in vertical stiffness, vertical and horizontal force, and impulse. Functional and effective propulsive force (2.95%, 2.88%) and impulse (3.40%, 3.38%) were significantly (p < 0.05) greater with LB5% than UB5%. Wearable resistance may be used to increase muscular kinetics during running without negatively impacting spatio-temporal variables. The application of these findings will vary depending on athlete goals. Future longitudinal studies are required to validate training contentions.

UR - http://www.scopus.com/inward/record.url?scp=85055156807&partnerID=8YFLogxK

U2 - 10.1080/14763141.2018.1508490

DO - 10.1080/14763141.2018.1508490

M3 - Article

SP - 1

EP - 19

JO - Sports Biomechanics

JF - Sports Biomechanics

SN - 1476-3141

ER -