Assessing the Reliability of Ultrasound Imaging to Examine Radial Nerve Excursion

Ben Kasehagen, Richard Ellis, Grant Mawston, Scott Allen, Wayne Hing

Research output: Contribution to journalArticleResearchpeer-review

7 Citations (Scopus)

Abstract

Ultrasound imaging allows cost effective in vivo analysis for quantifying peripheral nerve excursion. This study used ultrasound imaging to quantify longitudinal radial nerve excursion during various active and passive wrist movements in healthy participants. Frame-by-frame cross-correlation software allowed calculation of nerve excursion from video sequences. The reliability of ultrasound measurement of longitudinal radial nerve excursion was moderate to high (intraclass correlation coefficient range = 0.63-0.86, standard error of measurement 0.19-0.48). Radial nerve excursion ranged from 0.41 to 4.03 mm induced by wrist flexion and 0.28 to 2.91 mm induced by wrist ulnar deviation. No significant difference was seen in radial nerve excursion during either wrist movement (p > 0.05). Wrist movements performed in forearm supination produced larger overall nerve excursion (1.41 ± 0.32 mm) compared with those performed in forearm pronation (1.06 ± 0.31 mm) (p < 0.01). Real-time ultrasound is a reliable, cost-effective, in vivo method for analysis of radial nerve excursion.

Original languageEnglish
Pages (from-to)1651-1659
Number of pages9
JournalUltrasound in Medicine and Biology
Volume42
Issue number7
DOIs
Publication statusPublished - Jul 2016

Fingerprint

Radial Nerve
nerves
Wrist
wrist
Ultrasonography
Forearm
forearm
Pronation
Supination
Costs and Cost Analysis
Peripheral Nerves
costs
Healthy Volunteers
Software
correlation coefficients
cross correlation
computer programs
deviation

Cite this

Kasehagen, Ben ; Ellis, Richard ; Mawston, Grant ; Allen, Scott ; Hing, Wayne. / Assessing the Reliability of Ultrasound Imaging to Examine Radial Nerve Excursion. In: Ultrasound in Medicine and Biology. 2016 ; Vol. 42, No. 7. pp. 1651-1659.
@article{bff7cb67a0ca47a0ac43a19e4a6b4af4,
title = "Assessing the Reliability of Ultrasound Imaging to Examine Radial Nerve Excursion",
abstract = "Ultrasound imaging allows cost effective in vivo analysis for quantifying peripheral nerve excursion. This study used ultrasound imaging to quantify longitudinal radial nerve excursion during various active and passive wrist movements in healthy participants. Frame-by-frame cross-correlation software allowed calculation of nerve excursion from video sequences. The reliability of ultrasound measurement of longitudinal radial nerve excursion was moderate to high (intraclass correlation coefficient range = 0.63-0.86, standard error of measurement 0.19-0.48). Radial nerve excursion ranged from 0.41 to 4.03 mm induced by wrist flexion and 0.28 to 2.91 mm induced by wrist ulnar deviation. No significant difference was seen in radial nerve excursion during either wrist movement (p > 0.05). Wrist movements performed in forearm supination produced larger overall nerve excursion (1.41 ± 0.32 mm) compared with those performed in forearm pronation (1.06 ± 0.31 mm) (p < 0.01). Real-time ultrasound is a reliable, cost-effective, in vivo method for analysis of radial nerve excursion.",
author = "Ben Kasehagen and Richard Ellis and Grant Mawston and Scott Allen and Wayne Hing",
note = "Copyright {\circledC} 2016 The Authors. Published by Elsevier Inc. All rights reserved.",
year = "2016",
month = "7",
doi = "10.1016/j.ultrasmedbio.2016.02.013",
language = "English",
volume = "42",
pages = "1651--1659",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier",
number = "7",

}

Assessing the Reliability of Ultrasound Imaging to Examine Radial Nerve Excursion. / Kasehagen, Ben; Ellis, Richard; Mawston, Grant; Allen, Scott; Hing, Wayne.

In: Ultrasound in Medicine and Biology, Vol. 42, No. 7, 07.2016, p. 1651-1659.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Assessing the Reliability of Ultrasound Imaging to Examine Radial Nerve Excursion

AU - Kasehagen, Ben

AU - Ellis, Richard

AU - Mawston, Grant

AU - Allen, Scott

AU - Hing, Wayne

N1 - Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

PY - 2016/7

Y1 - 2016/7

N2 - Ultrasound imaging allows cost effective in vivo analysis for quantifying peripheral nerve excursion. This study used ultrasound imaging to quantify longitudinal radial nerve excursion during various active and passive wrist movements in healthy participants. Frame-by-frame cross-correlation software allowed calculation of nerve excursion from video sequences. The reliability of ultrasound measurement of longitudinal radial nerve excursion was moderate to high (intraclass correlation coefficient range = 0.63-0.86, standard error of measurement 0.19-0.48). Radial nerve excursion ranged from 0.41 to 4.03 mm induced by wrist flexion and 0.28 to 2.91 mm induced by wrist ulnar deviation. No significant difference was seen in radial nerve excursion during either wrist movement (p > 0.05). Wrist movements performed in forearm supination produced larger overall nerve excursion (1.41 ± 0.32 mm) compared with those performed in forearm pronation (1.06 ± 0.31 mm) (p < 0.01). Real-time ultrasound is a reliable, cost-effective, in vivo method for analysis of radial nerve excursion.

AB - Ultrasound imaging allows cost effective in vivo analysis for quantifying peripheral nerve excursion. This study used ultrasound imaging to quantify longitudinal radial nerve excursion during various active and passive wrist movements in healthy participants. Frame-by-frame cross-correlation software allowed calculation of nerve excursion from video sequences. The reliability of ultrasound measurement of longitudinal radial nerve excursion was moderate to high (intraclass correlation coefficient range = 0.63-0.86, standard error of measurement 0.19-0.48). Radial nerve excursion ranged from 0.41 to 4.03 mm induced by wrist flexion and 0.28 to 2.91 mm induced by wrist ulnar deviation. No significant difference was seen in radial nerve excursion during either wrist movement (p > 0.05). Wrist movements performed in forearm supination produced larger overall nerve excursion (1.41 ± 0.32 mm) compared with those performed in forearm pronation (1.06 ± 0.31 mm) (p < 0.01). Real-time ultrasound is a reliable, cost-effective, in vivo method for analysis of radial nerve excursion.

UR - http://www.scopus.com/inward/record.url?scp=84979491309&partnerID=8YFLogxK

U2 - 10.1016/j.ultrasmedbio.2016.02.013

DO - 10.1016/j.ultrasmedbio.2016.02.013

M3 - Article

VL - 42

SP - 1651

EP - 1659

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 7

ER -