Abstract
Objective: This paper introduces a new protocol for the measurement of post-cranial bones in computed tomography using slab maximum intensity projection.
Materials and Methods: The steps of the protocol are described and illustrated. Repeatability and accuracy are established through inter and intra observer testing evaluated using TEM, rTEM, and R.
Results: The protocol performed well in both repeatability and accuracy testing.
Conclusion: The protocol yields highly repeatable and accurate measurements.
| Original language | English |
|---|---|
| Article number | 200354 |
| Journal | Forensic Imaging |
| Volume | 20 |
| Early online date | 20 Jan 2020 |
| DOIs | |
| Publication status | Published - Mar 2020 |
| Externally published | Yes |